thanks for info as I posted above I did check the hi switch and no luck. 6-11 Months $1,337.00. Paul 79a9809, f171000329, f17-1000-329, F176013329, F17-6013-329, 99a9809, M6X0886, 989809, 799809, 999809, KMN2099809, KM N20 99809, ABPN2099809, ABP N20 99809, FLT99809, RX79A9809RMANRF , RX79A9809RMAN , RX79A9809RMAN. In order for a GoldTop fan clutch to operate properly, there must be between 90 120 psi of air pressure going into the fan clutch. It has online access to all inventory at Vander Haag's and has online parts and used truck locating services. I Replaced the clutch 60 days ago was bad then and would not engage at all, o rings were out and rough bearings. only possible thing is 2 things imo. It is an electric solenoid that turns the fan on and off. When your fan clutch won't engage, this usually means that your GoldTop is out of friction. Repeat Steps 1-3 for the N.O. And if I used a battery to the fan solenoid and fan then turned off it wont be the solenoid though would it? 0000011902 00000 n 0000447207 00000 n 0000016627 00000 n #QR]h0[EUjU UhST&N'eZ:_H 8_k{eeO+M?Xsd*1k/.q wrYdoIHc!&]*o*mil. Each company we work with has specific experience requirements for their drivers. GoldTop fan clutches engage when there is no air reaching the fan clutch. Discussion in 'Peterbilt Forum' started by Perchie15, Jan 7, 2022. Air cylonoid on the fire wall. Without your consent employers will not be able to contact with job offers, would you like to opt-in now? What does the ECM look at in order to turn the fan on and off? If your fan blade does not spin, your fan clutch is properly engaged. When replacing a Kysor-style fan clutch, you must always replace the hub (pulley) bearings at the same time. (TAKE A LOOK (GOOD USED/ TESTED) OEM Horton Fan Clutch off Caterpillar C15 Diesel Engine, for sale!!!!! Remove the jumper wire to exhaust the air and disengage the Fan Clutch. 0000408013 00000 n When I turn the engine off, voltage at the harness spikes to 13.45 volts which energizes the solenoid to disengage the fan briefly. You may pre-pay for the freight to return your core during the checkout process, or ship using your own method. It is conveniently located off Interstate 435 and Interstate 70. If your fan blade does not spin, your fan clutch is properly engaged. To determine the required bearing kit for your hub, enter the hub part number in the search field below, find the part number of the bearing kit you need on the dropdown below, or click on the 'Learn More' link below. C15. 5+ Years, Please select ALL of your current, valid drivers licenses. Job Listing Rules. Create Estimate. . P/N: (USED) Horton Fan Clutch for Caterpillar C15 on Peterbilt 387 Application, for sale!!!! They tear down and rebuild thousands of fan clutches every year. Privacy | (CHECK CHART IN (USED) Horton Fan Clutch off Caterpillar C15/ C16 Diesel Engine, for 2002-2005 International 9400 (CORE) Horton Fan Clutch, Fits on Caterpillar C15, C16, 3406 Diesel Engine, on International 9400 (USED) Horton Fan Clutch off Caterpillar C15, C16 Engine for a 2004-2007 Kenworth T800 and T600 (GOOD USED/ TESTED) Horton Fan Clutch for Caterpillar C15 & C16 ACERT Diesel Engine, for (GOOD USED/ TESTED) Horton Fan Clutch for Caterpillar C15, C16, Diesel Engine, for (USED) Horton Fan Clutch, Fits on Caterpillar C15 + C16 Diesel Engine on Kenworth T2000 (GOOD USED/ TESTED) OEM Horton Fan Clutch for Caterpillar C15 Acert and C16 Acert Diesel Engine, (GOOD USED/ TESTED) OEM Horton Fan Clutch off Caterpillar C15 Diesel Engine, for sale!!!!! 0000003355 00000 n C. . Every month 400 people find a job with the help of TruckersReport. You need a minimum of 90 psi, right at the entry point of your fan clutch, in order for it to operate correctly. Fan switch on the top of the air dryer for the AC. We first started having trouble with the a/c not cooling properly, after spending around $800 at TA to do nothing, the truck finally made its way home. For convenience we can ship parts directly to you, or you can pick up at one of our 9 locations across the Midwest. 0000001471 00000 n ;&fEH9B],5r87K'LiBm4;nRA9ROFNE+PVjc/.um+[/OeMJA%za0#b'=_0CYg]jlb!%C'i YXzO5'DPxbib,O}l`rp\0@xm^ L43B4},~P:S6,Ztd ;>g|-oB)&)GsA[U "GBcs>ieNS "2T7DaFUi>Q$$:u+b5ujrX%Vn X the sensors use the ground to control the fan switch. Give us a call today. 999161. 0000007227 00000 n . After checking things over we found the a/c system is doing its thing, its full of freon, compressor is . These years of experience and our better than OEM quality standards ensure that your professionally rebuilt fan clutch operates well beyond the 3-year/300,000 mile warranty. There are fan blades in operation today that require more torque than current fan clutches can produce. C15 Engine Fan. They are like 20 bucks on ebay. 0000446887 00000 n 6-11 Months Caterpillar Fan Clutch Kit Masters Part # 98647. Anyone know where or what it is ? Have followed gray wire 3191 from switch to firewall and ecm on engine. that we can continue to improve TPI to suit your needs. You are purchasing a Kysor-style fan clutch. Cat ecm's do not read oil temp.Fan is controlled by water temp.intake air temp and ac pressure switch.Good luck. 4 Years In order for a GoldTop fan clutch to operate properly, there must be between 90 120 psi of air pressure going into the fan clutch. Without your consent employers will not be able to contact with job offers, would you like to opt-in now? Kit Masters patented Auto Lock feature will AUTOMATICALLY LOCK UP fan clutches when the friction material nears the end of its life, allowing the vehicle to finish its trip. Yes, I want to pre-pay for Core Return Freight. Or the fan clutch? 0000448852 00000 n 0000003992 00000 n 3 Years Would you like to pre-pay for the return freight? 2 Years To test this, shut off your truck and try to spin your fan blade. 0000002216 00000 n I give my express consent authorizing TruckersReport and its. 0000447840 00000 n 0000005230 00000 n 5+ Years, Please select ALL of your current, valid drivers licenses. 6-11 Months The key reason for premature spring-engaged fan clutch failures is LACK OF TORQUE. My T800 KW C15 Clutch fan won't shout off? In CDL School Now 2. The fan will not engage . Any thoughts on were to look? If disconnect switch fan stays engaged with key in on position. Your fan clutch needs to be rebuilt or replaced. 1-5 Months Repair or replace the fan clutch in your shop, at your convenience. Your fan clutch needs to be rebuilt or replaced. 18643 Views 9 Replies 8 Participants Last post by chunkchange, Dec 29, 2011. Failure to install new hub bearings with your clutch will void your warranty. No outside labor costs or tow bills. To test this, shut . 0000006239 00000 n trailer << /Size 199 /Info 141 0 R /Encrypt 159 0 R /Root 158 0 R /Prev 915261 /ID[<41ad620ddc5a1a05a203bca0c1d9acab><4c3fe90ba25715df1fb33f32324a1952>] >> startxref 0 %%EOF 158 0 obj << /Type /Catalog /Pages 144 0 R /Metadata 142 0 R /JT 156 0 R /PageLabels 140 0 R >> endobj 159 0 obj << /Filter /Standard /R 2 /O ( UV.`Dz-#_m_}g) /U (r~-`\\k5. If you can spin your fan blade, then you have no friction left and your fan clutch assembly needs to be rebuilt or replaced. Manual fan override switch on my Cat C15 in a 2007 Peterbilt 379 won't engage fan. I don't want to purchase a hub bearing kit at this time. You need a minimum of 90 psi, right at the entry point of your fan clutch, in order for it to operate correctly. CAT C15 Fan clutch turns well, mount included . When replacing a Kysor-style fan clutch, you must always replace the hub (pulley) bearings at the same time. When replacing a Kysor-style fan clutch, you must always replace the hub (pulley) bearings at the same time. Peterbilt / Caterpillar C16. Its used truck parts and service facility is just 6 miles south of Council Bluffs on Interstate 29. Kit Masters patented Auto Lock feature will AUTOMATICALLY LOCK UP fan clutches when the friction material nears the end of its life, allowing the vehicle to finish its trip. Do you have any other details that could be helpful? Let TPI find the part for you. (TAKE (USED) Horton Fan Clutch off Caterpillar C15, C16, Diesel Engine, for sale!!!! Job Listing Rules. Our Des Moines location is home to the largest VanderHaag's showroom, and has a storage and shop area over 20,000 sq feet. In CDL School Now A javascript enabled browser will give the best use the search features of this site. The solenoid on the fire wall? The key reason for premature spring-engaged fan clutch failures is LACK OF TORQUE. Privacy | I Need CDL Training Without your consent employers will not be able to contact with job offers, would you like to opt-in now? p.qMQvJ` |*"@gJK*7@&=YLEcG]M^ko&KO9:~!63Q{o-b.al 0000005252 00000 n To test this, shut off your . P/N: (GOOD USED/ TESTED) Borg Warner Fan Clutch off Caterpillar C15 Engine, for sale!! Or the fan clutch? 515 Detroit. I give my express consent authorizing TruckersReport and its. Brand: HORTON. When your fan clutch won't engage, this usually means that your GoldTop is out of friction. 0000446722 00000 n Our team is ready to assist you! 0000007250 00000 n 157 0 obj << /Linearized 1 /O 160 /H [ 1471 527 ] /L 918531 /E 449069 /N 28 /T 915272 >> endobj xref 157 42 0000000016 00000 n 0000406630 00000 n Some of the services it offers are frame modification and alterations, equipment installation, part installation and service work, as well as paint and body repair. Cat C15 fan clutch & switch ETC llc 80K views 6 years ago Horton Fan Clutch | W900 is back going again Farming Fixing & Fabricating 26K views 2 years ago Engine fan stays on.. You have a break in that harness from that solenoid to the ecm. In order for you to receive the best possible offers, please make sure your answers above are accurate prior to submitting. If you can spin your fan blade, then you have no friction left and your fan clutch assembly needs to be rebuilt or replaced. Cookie Policy | They tear down and rebuild thousands of fan clutches every year. If you have more than 90 psi, right at the entry point of your fan clutch, and your fan clutch still wont disengage, the Auto Lock feature on your fan clutch has kicked in. /# 2-speed equivalent: 98647-2 . Base (USED) 2004- 2005 Horton Fan Clutch, Fits on Caterpillar C15/C16 Diesel Engine, for 2004-2005 Caterpillar C15 Fan Clutch/Hub Heavy Truck Parts For Sale. Situated just northeast of I-465 and I-70 in West Indianapolis, we are stocked with a large inventory of Used, Rebuilt, and New truck parts. 0000001209 00000 n First, check your air pressure right at the entry point of your fan clutch. http://www.thetruckersreport.com/trtliner-forum/184518-where-to-get-manuals.html. If it does, I would follow the wires from the control solenoid. New temp switch in thermostat housing. The wire # p118 goes to solenoid and no power. When your fan clutch wont engage, this usually means that your GoldTop is out of friction. No air leak at the fan clutch. This product includes a core charge. This product includes a core charge. Peterbilt / Caterpillar C15 Replaces OEM Part #: 79a9809, f171000329, f17-1000-329, F176013329, F17-6013-329, 99a9809, M6X0886, 989809, 799809, 999809, KMN2099809, KM N20 99809, ABPN2099809, ABP N20 99809, FLT99809, RX79A9809RMANRF , RX79A9809RMAN , RX79A9809RMAN, . Having trouble finding your part? Our Auto Lock feature prevents on-the-road failures. Part number 65761999 Peterbilt / Caterpillar C15. AC compressor won't engage. Our GoldTop fan clutches pack over 5,000 inch-lbs of torque. Nobody knows how to rebuild a fan clutch like Kit Masters technicians. Combine this with our excellent product knowledge and access to our 7 other locations' inventory, our goal is to make parts available for you to get your truck operating as soon as possible. These years of experience and our better than OEM quality standards ensure that your professionally rebuilt fan clutch operates well beyond the 3-year/300,000 mile warranty. Unrivaled quality and performance make GoldTop fan clutches by Kit Masters an unbeatable value. Our Auto Lock feature prevents on-the-road failures. We are excited to bring our quality recycled truck parts to Texas, along with stocking a large array of new and rebuilt components. If they are both plugged in it will not engage even if AC is on high . Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- Best Selling in Fans & Shrouds. 0000009495 00000 n When your friction material nears the end of its life, the Auto Lock feature fully engages your fan clutch to help you get to a service shop to get your fan clutch maintained, instead of leaving you stranded on the side of the road. Had a fan come on and can't figure out why it won't shut off. ft. of storage and service facilities with over 30 acres of salvage units and parts storage. Keep hands and tools clear of the fan blades. Failure to install new hub bearings with your clutch will void your warranty. Repair or replace the fan clutch in your shop, at your convenience. Job Listing Rules, God I wish. 0000006217 00000 n 0000448127 00000 n It offers frame modifications and alterations, equipment installation, and a complete repair facility. In order for a GoldTop fan clutch to operate properly, there must be between 90 120 psi of air pressure going into the fan clutch. Peterbilt / Caterpillar C15 Replaces OEM Part #: 999815, 79a9815, 989815, KMN2099815, KM N20 99815, ABPN2099815, ABP N20 99815, FLT99815, RX79A9815RMANRF , RX79A9815RMAN, . Vander Haag's is your destination for high quality new and used heavy duty truck parts, semi truck salvage, trucks, trailers, equipment and service. Our GoldTop fan clutches pack over 5,000 inch-lbs of torque. Engages at engine start and runs all day. Each company we work with has specific experience requirements for their drivers. Yes, I want to pre-pay for Core Return Freight. Vander Haag's Louisville is located just south of I-264 and west of I-65, near the Muhammad Ali International Airport. 4 Years When your friction material nears the end of its life, the Auto Lock feature fully engages your fan clutch to help you get to a service shop to get your fan clutch maintained, instead of leaving you stranded on the side of the road. (LOOK AT CAT C15 Fan clutch turns well, mount included . There are fan blades in operation today that require more torque than current fan clutches can produce. !k}>'W;W/Xh`dj^pfD zU[OINn^,6 endstream endobj 167 0 obj 885 endobj 168 0 obj << /Filter /FlateDecode /Length 167 0 R >> stream These years of experience and our better than OEM quality standards ensure that your professionally rebuilt fan clutch operates well beyond the 3-year/300,000 mile warranty. Our GoldTop fan clutches pack over 5,000 inch-lbs of torque. Unrivaled quality and performance make GoldTop fan clutches by Kit Masters an unbeatable value. The compressor\s pressure gauge does not accurately show how much air pressure is actually entering the fan clutch. The Spencer location is also where the Vander Haag's Corporate Headquarters are. If you have more than 90 psi, right at the entry point of your fan clutch, and your fan clutch still wont disengage, the Auto Lock feature on your fan clutch has kicked in. 0000447591 00000 n When the fan drive is disengaged (no engine cooling required, AC off), depress the brake pedal several times to bleed the system air pressure below 90 psi Once the air pressure goes below 90 psi, the fan drive should engage. Cookie Policy | Where are you located. It just leads to the ecm no relay of such. Sign up to the Truck Parts Inventory newsletter. Please select the number of verifiable months youve been driving professionally using your Class A CDL within the last 3 years. 6-11 Months Please note that the part information is already included in the email that is sent to the sellers. Our Spencer location has over forty acres of part and vehicle storage with over 100,000 sq.

Ansible Pxe Boot, Shamari Devoe Net Worth 2021, Used Ice Shanty For Sale, Articles C

cat c15 fan clutch won't engage